Shanghai Hengxiang Optical Electronic Co., Ltd. 86-21-54613487 fang@shhxgd.cn
Conventional Incremental Flange Encoder Totem Pole Output S52F With Radial Socket

Conventional Incremental Flange Encoder Totem Pole Output S52F With Radial Socket

  • High Light

    optical sensor encoder

    ,

    2048 pulse encoder

  • External diameter
    52mm
  • Product Name
    S52F Series Solid Shaft Encoder
  • Flange Dimension
    52mm X 52mm
  • Shaft Load
    Radial 60N; Axial 60N
  • Supply voltage
    DC5V ; DC8-30V
  • Insulation Resistance
    10MΩ
  • IP grade
    IP50 ; IP65
  • Consumption Current
    100mA MAX
  • Place of Origin
    Shanghai,China
  • Brand Name
    HENGXIANG
  • Certification
    CE,ISO9001
  • Model Number
    S52F Series incremental encoder
  • Minimum Order Quantity
    1pcs encoder to start order
  • Price
    negotiable
  • Packaging Details
    each 1 piece was packed into single carton box
  • Delivery Time
    3-5 working days for sample order, 7-15 working days for mass order
  • Payment Terms
    D/A, D/P, T/T, Western Union, Credit Card, Master Card,Paypal, etc
  • Supply Ability
    100K pieces per year

Conventional Incremental Flange Encoder Totem Pole Output S52F With Radial Socket

Conventional incremental encoder totem pole output S52F flange encoder with radial socket

 

About Encoder Vibration

Vibration acting on an encoder always cause wrong pulse easily.

So we have to pay more attention to encoder working place.

The more pulse per round, the narrower groovy spacing of grating, ore effect to encoder by vibration, when motor speed is low or even stopped, vibration acting on encoder shaft or encoder shell would cause grating vibration, in this way, encoder might show wrong pulse signal.

 

K52F Series encoder Specification

Items Basic parameters
Brand HENGXIANG
Encoder type Incremental encoder
External diameter 52mm
Thickness 44mm
Flange dimension 52mm x 52mm
Installation dimension 44mm x 44mm
Shaft length 16mm
Solid Shaft diameter 10mm(D shape)
Output mode NPN Collector open circuit output
  Voltage output
  Push-pull output
  Difference output Long line drive (26LS31)
Compatible RS422
Long line drive (RT7272)
Protection grade IP50 ; IP65
Cable length 1M (cable length could be added appropriately by
require, but it need payment individually)
Consumption current 100mA MAX
Environmental temperature Operating:-20 ~+85°;storage:-25 ~+90°
Environmental humidity Operating and storage: 35-85%RH(noncondensing)
Vibration(endure) Amplitude 0.75mm,5-55Hz,2 hours for three axis individually
Sock(endure) 490m/s2 ,11 ms three times for X,Y,Z direction individually
Shaft Material Stainless steel
Shell Material die cast aluminum
Cable length 1000mm(cable with shielding)
Certification CE
package Carton box
Net weight About 300g (with package)

 

Lead time

1. for 1-10 samples: 3-5 working days

2. for 20-50 mass production: 7-10 working days

3. for over 100pcs, production will be discussed with customers and ship on time

 

Packing Details

Each single encoder is packed into a single safe carton with protecting bubble.

Then all encoders will be put into a bigger carton to prepare shipment.

 

Principle of encoder

With proper connections you can use the Push Pull interface to replace true open collector circuits by using an external diode connected in a way to limit the direction of the current for RS422 (TTL) circuits provide a constant 5 V signal level that is not dependent on the supply voltage. Two supply voltage ranges can be selected: From 4.75 to 5.5 VDC (can be used to replace open collector output drivers) or from 8 to 30 VDC. Using differential signals the output fully complies to the RS422 standard.

 

The differential outputs have the highest frequency response capability and the best noise immunity. To ensure this the receiver should also be a differential.

Replacement of Older Output Drivers

 

A logic gate interprets certain input voltages as high (logic 1) or low (logic 0).

TTL (transistor-transistor-logic): A signal above 2 V is interpreted as logic 1 and a signal less than 0.8 V is interpreted as logic 0. The output voltage ranges between 0-5 V.

HTL (high-threshold-logic): A signal above 3 V is a logic 1 and a signal less than 1 V is a logic 0. The high output signal level is dependent from the supply voltage. Because of the higher voltage difference between logic 0 and 1, the HTL logic is more immune to interference and more resistant against electrical noise.

 

Conventional Incremental Flange Encoder Totem Pole Output S52F With Radial Socket 0